Avant APSON 3kva Tower Standard Backup
Sold Out
Rs.47,500.00
Description
Avant APSON 3Kva Online – UPS
True On-Line UPS provides high-density, double-conversion, online power protection for critical servers, CCTV applications,voice/data networks, medical labs and for light industrial applications.
The AVANT On-Line is capable of supporting loads from 1 kVA – 10 kVA in a rack/tower convertible chassis.
Features
– 50Hz//60Hz frequency convertor mode
– Eco mode operation for energy saving (ECO)
– Generator compatible
– Cold start
– Wide input voltage range (110~300Vac)
– Input power factor 0.99 (with PFC)
– Input current harmonic (THDi) <3%
– Output power factor 0.9
– Maximum charging current 12A (Long run unit)
– Charging current can be set by LCD
– Smart battery charging design for optimized battery performance
– N+1 Parallel redundancy
– Sel-Testing when UPS starts
Criteria |
Details |
| Capacity | 3000VA/2700W |
| Phase | Single Phase in /Single phase out with ground |
| Input Voltage | 200V/208V/220/230/240Vac |
| Operating Voltage | 125V – 175V @ 60% to 100% Load, Upper limit upto 290Vac ± 5% |
| Operating Frequency | 40Hz to 70Hz without calling battery |
| Power factor | 0.99 |
| Harmonic Distortion THDi | <3% (100% Linear load) |
| Output Voltage | 200V/208V/220/230/240Vac selectable |
| Voltage regulation with ± 1% | |
| Output Power factor | 0.9 |
| Output Frequency | Online Mode 47Hz – 53Hz or 57Hz-63Hz |
| Battery Mode – 50Hz ± 0.1Hz | |
| Waveform | Pure sine wave |
| Harmonic Distortion THDv | ≤3% THD with linear load, |
| ≤5% THD with non – linear load | |
| Crest Factor | 3:01 |
| Transfer Time | AC to Bat – Zero |
| Sockets | Universal sockets + IEC |
| Efficiency | 92% |
| EPO | Available |
| Over Load Conditions | 105%-110% UPS Shut down after 10minutes at battery mode or transfer to bypass when utility is nomal |
| 110%-130% UPS Shut down after 01minutes at battery mode or transfer to bypass when utility is nomal | |
| >130% UPS Shut down after 05 seconds at battery mode or transfer to bypass when utility is nomal | |
| Short circuit | Hold whole system |
| Audible , Visual alarms | LED , LCD Display, Line fauly, Battery low, over load, system faults, Eco Mode, Bypass mode |
| Communication | USB, SNMP card Optional , Relay car Optional |
| Operating temperature | 0-40 degree celcius |
| Humidity | 20 to 90% RH @ 0-40 degree celcius |
| Altitude | <1500m |
| Noise level | Less than 50dBA @ 1 meter |
| Type , No of Battery | 12V-9Ah * 6 No's |
| Backup time – standard | 07 to 10 minutes depending on the load profile |
| Backup time – long | On request long backup model can be provided. Long backup depending on the capacity of batteries. |
| Typical recharge time | 4 hours recover 90% capacity |
| Charging current | 1A (Standard unit) Long run unit 10A Maximum |
| Safety | IEC/EN62040-1, IEC/EN60950-1 |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
| Dimensions WxHxD (mm) | 191x337x460 |
| Net Weight | 28 |